Isuzu wastewater pump truck is a specialized vehicle designed for pumping and transporting wastewater and sludge efficiently. It consists of several main components that work together to ensure effective wastewater management.
Mounted on the chassis is the vacuum tank, which is the key component for holding and transporting wastewater. The vacuum tank is typically made of corrosion-resistant materials to withstand the corrosive nature of sewage. It is designed to have a large capacity, allowing for the efficient collection and transportation of significant amounts of wastewater. The tank is equipped with suction and discharge connections for the intake and outflow of wastewater.
Work capacity:
10,000 LTruck model:
PT5150GXWEngine power:
205 HPEngine type:
Isuzu 4HK1-TCAxle drive:
4x2Gear box:
Isuzu MSBRemarks:
Secondary filtration systemIsuzu Wastewater Pump Truck is a specialized vehicle used for sewage discharge and water pumping. It is mainly composed of chassis, tank, water pump system, water inlet channel, drainage channel and control system.
The chassis is the basic supporting structure of the entire vehicle and is usually provided by Isuzu. The chassis has the characteristics of strong load-bearing capacity, good stability and high impact resistance to ensure reliable operation of the vehicle under heavy loads and harsh road conditions.
The tank body is customized by POWERSTAR Company and is usually made of large-capacity polyethylene material with good corrosion resistance and sealing properties. There is a water inlet and a drainage port inside the tank for filling and discharging sewage. In addition, the tank is also equipped with instruments such as liquid level gauges and pressure gauges to monitor and control the liquid level and pressure in the tank.
The Sewer Cleaning & Vacuum Truck Isuzu is equipped with advanced features and innovative functionalities, making it the ideal choice for municipalities, construction sites, and industrial facilities. Its powerful vacuum system, combined with high-pressure water jetting capabilities, ensures thorough and effective cleaning of sewer lines, preventing blockages and promoting hygienic environments.
The Main Specifications of the Sewage Suction Truck
Isuzu FTR waste water tanker truck Complete Vehicle Parameter | |
Vehicle | ISUZU vacuum sewage truck |
Overall dimension (mm) | 7850×2470×3200 |
Sewage tank (m3) | 10 |
Gross vehicle weight (kg) | Appro×18000 |
Curb weight (kg) | Appro×8048 |
Payload (kg) | Appro×9757 |
Wheel base (mm) | 4500 |
Max speed (km/h) | 95 |
Chassis Parameter | |
Cabin | Flat top cabin,a sleeper,power steering, air conditioner, 3 passengers,left hand drive |
Drive form | 4×2 |
Engine | Brand: ISUZU Model: 4HK1-TCG40, 205 hp Type: diesel, turbocharged, 6 cylinder. Displacement: 5193ml Emission standard: Euro 4 |
Transmission | 6 forward,1 reverse, manual operated |
Tire model | 10.00-20 |
No.of tires | 6pcs, with 1pc spare tire |
Superstructure Parameter | |
Characteristic | 1. Sewage tank volume 10000 liter. 2. Sewage tank material is carbon steel,thickness 6mm. 3. Sewage suction pipe 1pcs, length 7m. 4. Hydraulic lifting sewage tank,rear cover can open. 5. Equipped with PTO. 6. Equipped with vacuum pump. 7. Equipped with oil water separator, overflow valve,looking sewage window, self flow exit,hand washing device. |
Performance | (1) Vertical suction ≥ 7m. (2) Pumping speed : 45L/s. (3) Intake and exhaust diameter: 50mm. (4) Full tank pumping time ≤ 5min. (5) Sewage tank emptying time ≤ 4min. |
Isuzu FTR waste water pump truck
Isuzu FTR waste water pum tanker truck
The water pump system is the core component of the entire vehicle and consists of an electric motor, water pump and hydraulic system. The electric motor drives the water pump to operate, sucking sewage into the tank through the water inlet channel, and then discharging the sewage through the drainage channel. The hydraulic system is used to control the start, stop and speed adjustment of the water pump to adapt to different sewage pumping needs.
The water inlet channel refers to the path through which sewage is introduced into the tank from the outside, usually connected to the tank through the suction pump water inlet joint. The water inlet channel has ancillary equipment such as valves and filters to prevent impurities from entering the tank and affecting the normal operation of the water pump.
Jurop vacuum pump for Isuzu waste pump tanker truck
Isuzu waste tanker suction truck with JUROP PN106D pump
Isuzu wastewater pump truck is a specialized vehicle designed for the efficient handling of wastewater and sewage. It plays a crucial role in maintaining sanitation and public health by effectively removing and disposing of wastewater from various sources. The following are the step-by-step procedures involved in the operation of an Isuzu wastewater pump truck.
1. Inspection and Preparation:
Before starting any work, the operator needs to inspect the vehicle thoroughly. This includes checking the fuel levels, engine oil, tires, brakes, and other essential components. The tank for holding wastewater should also be clean and well-maintained. Once the inspection is complete, the pump truck is prepared for operation.
2. Identifying the Collection Point:
The next step is to identify the source of wastewater that needs to be pumped out. This can be a residential building, commercial facility, or public sewer system. The operator ensures that the truck is positioned correctly and safely near the collection point.
3. Connecting the Hoses:
The wastewater pump truck is equipped with long hoses that are connected to the designated points. The operator carefully attaches the hoses to the collection point and ensures a secure connection to prevent any leaks.
4. Activating the Pump System:
Once the hoses are securely connected, the operator activates the pump system. The powerful pump mechanism is engaged, creating suction that allows the wastewater to flow into the truck's storage tank. The pump truck efficiently collects and transports wastewater, ensuring it does not create any environmental hazards or health risks.
5. Monitoring the Process:
As the wastewater is being pumped out, the operator closely monitors the process to ensure smooth operation. They keep an eye on the flow rate, pressure, and overall functioning of the pump truck. Any irregularities or issues are promptly addressed to prevent complications.